HP StorageWorks 1510i - Modular Smart Array User Manual page 124

Active/active firmware v2.0 or later
Hide thumbs Also See for StorageWorks 1510i - Modular Smart Array:
Table of Contents

Advertisement

Message
319 FAN FLASH DONE
ON BOX #<n>
320 FAN FLASH
FAILED ON BOX #<n>
321 BATTERIES LOW,
FLASH REFUSED
330 AUTO-UPGRADE
IN PROGRESS
331 AUTO-UPGRADE
DONE
332 AUTO-UPGRADE
FAILED
333 AUTO-UPGRADE
REQUIRES REBOOT
400 STORAGE BOX
#<n> FAN OK
401 STORAGE BOX
#<n> FAN FAILED
402 STORAGE BOX
#<n> FAN DEGRADED
403 STORAGE BOX
#<n> FAN HOT
INSERTED
404 STORAGE BOX
#<n> FAN HOT
REMOVED
405 STORAGE BOX
#<n> TEMPERATURE
OK
124
MSA controller LCD panel message descriptions
Type
Description
Indicates that the array controller
Informational
has completed updating the
firmware on a fan module.
Indicates that the array controller
Error
was unable to update the firmware
on a fan module.
The array controller was unable to
proceed with a firmware flashing
or cloning operation because
Error
the cache batteries are low and
there is a risk of data loss if the
operation fails.
The array controller has detected
that firmware upgrades are needed
Informational
to other MSA components and is
preparing to perform the upgrade.
The array controller has completed
Informational
upgrading MSA components.
The array controller was unable to
Error
upgrade all MSA components.
The array controller completed
upgrading MSA components and
requires the MSA to be rebooted
Informational
before the upgrades can take
effect.
A fan in the specified storage
enclosure that was previously
Informational
marked as failed or degraded is
now operating normally.
A fan in the specified storage
enclosure has failed. The MSA
Error
may now be susceptible to
overheating if corrective action is
not taken.
An fan in the specified storage
Informational
enclosure has been hot added.
An fan in the specified storage
Informational
enclosure has been hot added.
A fan in the specified storage
Informational
enclosure has been removed.
The temperature in the specified
Informational
storage enclosure is now back in
the normal operating range.
Action
Retry the operation. Contact HP
support if the problem persists.
Allow the controller to charge its
batteries, and then retry the flash
operation.
Check previous error messages
to determine which components
failed to upgrade, and verify that
these components are working
properly. The upgrade can be
retried the next time the MSA is
rebooted.
Reboot the MSA to complete the
upgrade process.
Check all fans to ensure they are
operating. Replace any failed
fans.
Check all fans to ensure they are
operating. Replace any failed
fans.

Advertisement

Table of Contents
loading

Table of Contents