301 RECOVERY ROM
AUTOFLASH DONE
302 RECOVERY ROM
AUTOFLASH FAILED
303 ROM CLONING
STARTED
304 ROM CLONING
DONE
305 ROM CLONING
FAILED
306 FIRMWARE FLASH
STARTED
122
MSA controller LCD panel message descriptions
Type
Description
The array controller has successfully
completed the process of copying
Informational
the current active firmware image
into the backup recovery ROM.
The array controller failed to copy
the current active firmware image
Error
into the backup recovery ROM.
Recovery ROM support is disabled.
Indicates that the two array
controllers in the MSA do not
have the same version of firmware
on them. Therefore, one array
controller's version of the firmware
is copied on to the other array
controller. Both controllers must
be running the same version of
Informational
firmware in order for controller
redundancy to operate. If both
array controllers are in the
power-on sequence, the most
recent version of firmware is used.
If one array controller has already
completed the power-on sequence
and is now active, its version of
firmware is used even if less recent.
In dual-controller MSA only,
this indicates that the two array
controllers in an MSA have finished
copying one array controller's
Informational
version of firmware to the other
array controller. Both controllers
must be running the same version
of firmware in order for controller
redundancy to operate.
In dual-controller MSA only,
this indicates that the two array
controllers in an MSA failed to
copy one array controller's version
Error
of firmware to the other array
controller. Both controllers must
be running the same version of
firmware in order for controller
redundancy to operate.
The array controller in the MSA has
started the firmware flash process.
Informational
Do not turn off power to the system
until it has completed. This could
take several minutes.
Action
Remove the failing array controller,
wait 10 seconds, and then reinsert
the array controller, ensuring that
it is fully seated in the chassis.
The ROM autoflash process is
attempted again.
Should the issue persist, contact
HP support.
Remove the standby array
controller, wait 10 seconds, and
then reinsert the array controller
ensuring that it is fully seated in the
chassis. The ROM cloning process
is attempted again.
If the issue persists, contact HP
support.