GS g 0 m nL nH
[Function]
[Code]
[Range]
[Outline]
Hexadecima
[Caution]
Initializing maintenance counter
<1D>H<67>H<30>H<m><nL><nH>
m=0
20≦(nL+nH×256)≦70(nL=20、21、50、70、nH=0)
Set the value of resettable maintenance counter specified to 0.
nL, nH are used to set the maintenance counter number to (nL+nH×256).
Counter Number
Decimal
l
14
20
15
21
32
50
46
70
• This command, if used frequently, may destroy NV memory, thus write command to
NV memory shall be used less than [10 times/day] as a guideline.
• Along with processing this command, during data-writing to NV memory, printer
BUSY may occur. During the printer BUSY, to stop receive processing, this printer
prohibits the data sending (including real-time command) from host.
Counter [Unit]
Paper-feed line[line]
Head powering count [times]
Auto-cutter drive count [times]
Product operation time[hours]