MSW4-3: Paper heading cut
[Outline]
When cover is closed, feed paper about 13mm before cut.
ON (1) OPERATION: Paper heading cut is enabled.
OFF (0) OPERATION: Paper heading cut is disabled.
[Default]
ON (1) [Valid]
MSW4-4: Reserved [Fixed to OFF (0)]
MSW4-5: Reserved [Fixed to OFF (0)]
MSW4-6: Reserved [Fixed to OFF (0)]
MSW4-7: Reserved [Fixed to OFF (0)]
MSW4-8: Forcible partial cut
[Outline]
Select the operation taken when full cut command is received.
ON (1) OPERATION: When full cut command is received, partial cut, not full cut, is taken.
OFF (0) OPERATION: When full cut command is received, full cut is taken.
[Default]
ON (1) [Valid]
MSW5
MSW5-1: Buzzer
[Outline]
Select the enable/disable of buzzer.
ON (1) OPERATION: Disable buzzer
OFF (0) OPERATION: Enable buzzer.
[Default]
OFF (0) [Valid]
Feed & Cut at TOF
Partial only
Buzzer
When an error occurs or memory switch setting is changed manually, no buzzer
sounds.
When an error occurs or memory switch setting is changed manually, the buzzer
sounds.
OFF (0)
Invalid
OFF (0)
Invalid
OFF (0)
Valid
- 184 -
ON (1)
Valid
ON (1)
Valid
ON (1)
Invalid