Citizen CT-S2000 Command Reference Manual page 188

Line thermal printer
Hide thumbs Also See for CT-S2000:
Table of Contents

Advertisement

MSW7-2: Data length
[Outline]
Select the data length, which is a serial interface communication condition.
Enabled if DSW1-1 OFF is set [following memory switch setting].
[Default]
8 bits
MSW7-3: Stop bit
[Outline]
Select the stop bit, which is a serial interface communication condition.
Enabled if DSW1-1 OFF is set [following memory switch setting].
[Default]
1 bit
MSW7-4: Parity
[Outline]
Select the parity, which is a serial interface communication condition.
Enabled if DSW1-1 OFF is set [following memory switch setting].
[Default]
None
MSW7-5: Busy control
[Outline]
Select the busy control, which is a serial interface communication condition.
Enabled if DSW1-1 OFF is set [following memory switch setting].
[Default]
DTR/DSR
MSW7-6: DMA control
[Outline]
Select the enable/disable of DMA (Direct Memory Access) control.
[Default]
Valid
Data Length
Stop Bit
Parity
Flow Control
DMA control
Setting Value
7 bits, 8 bits
Setting Value
1 Bit, 2 Bits
Setting Value
NONE, ODD, EVEN
Setting Value
DTR/DSR, XON/XOFF
Setting Value
Valid, Invalid
- 186 -