GS C 1 n1 n2 n3 n4 n5 n6
[Function]
[Code]
[Range]
[Outline]
[Default]
[See Also]
[Sample Program]
[Print Results]
Setting the numbering counter mode (A)
<1D>H<43>H<31>H<n1><n2><n3><n4><n5><n6>
0≤ n1, n2, n3, n4, n5, n6 ≤255
This command sets the numbering (serial number counter) mode.
n1 + n2 x256 (n1 = remainder, n2 = quotient): Counter default
n3 + n4 x256 (n3 = remainder, n4 = quotient): Counter final value
n5: Counter step value
n6: Identical counter print counter
(n1 + n2 x256) < (n3 + n4 x256): Count-up system
(n1 + n2 x256) > (n3 + n4 x256): Count-down system
(n1 + n2 x256) = (n3 + n4 x256) or n5 = 0 or n6 = 0: Counter stop
n1 + n2 x256 = 1
n3 + n4 x256 = 65535
n5 = 1
n6 = 1
GS C0 , GS C2 , GS c , GS C ;
LPRINT CHR$(&H1D);"C0";
LPRINT CHR$(3); CHR$(0);
LPRINT CHR$(&H1D);"C1";
LPRINT CHR$(50); CHR$(0);
LPRINT CHR$(0); CHR$(0);
LPRINT CHR$(5); CHR$(2);
GOUSAB *CNT
LPRINT CHR$(&H1D);"C2";
LPRINT CHR$(5); CHR$(0); CHR$(10);
GOUSAB *CNT
END
50 50 45 45 40
5 0 50 45 40
*CNT
FOR I=1 TO 5
LPRINT CHR$(&H1D);"c";
NEXT I
LPRINT CHR$(&HA);
RETURN
When printing the counter value by setting a count-down
range = 0 to 50, step value = 5, repeat count = 2,
and starting value = 50.
When printing the counter value by setting a count-down
range to 0 to 50, step value = 5, repeat count = 1,
and starting value = 5, step cleared.