AT&T MERLIN LEGEND Release 4.0 Feature Reference page 81

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 4.0:
Table of Contents

Advertisement

Feature Reference
Basic Rate Interface (BRI)
At a Glance
Users Affected
Reports Affected
Mode
Telephones
System Programming
800 NI-BRI Module
Maximums
BRI modules
Factory Settings
Systemwide
Clock Synchronization
Source
Primary Clock
Clock
BRI
Service Profile Identifier
(SPID) assigned to BRI line
Directory Number (DN)
assigned to BRI line
Factory Settings
Timer and counter
thresholds for all BRI ports
in system
T200 Timer
T203 Timer
T303 Timer
T305 Timer
T308 Timer
Telephone users, operators, digital data users
System Set-Up
BRI Information
Key, Hybrid/PBX
All (display support on MLX sets only)
Specify 800 NI-BRI modules that provide primary, secondary,
and tertiary clock synchronization and source of clock
synchronization; also activate/deactivate clock:
More
Assign telephone numbers (SPID and DN) to BRI lines:
More
DN
Specify BRI timer settings:
More
5
Loop (not definable by system manager)
First port that is in service on an 800 NI-BRI module or first
100D module in service in control unit
Active
0 digits
0 digits
1000 ms (range 500–5000 ms, increments of 500 ms)
33 seconds (range 10–255 seconds, increments of 1 second)
4 seconds (range 2–10, increments of 1 second)
30 seconds (range 2–60, increments of 1 second)
4 seconds (range 2–10, increments of 1 second)
SPID
Basic Rate Interface (BRI)