PLC-HF10000L Expand Serial Command Functional Specifications
9.9 Lamp Status Read Commands
9.9.1 CR_LAMPREPL Command
Command
"CR_LAMPREPL" [CR]
Details
Get the information of Lamp Replacement time
Acceptable
Response
%1
Unacceptable
9.9.2 CR_LAMPMODE Command
Command
"CR_LAMPMODE" [CR]
Details
Get Lamp mode setting status
Acceptable
Response
%1
Unacceptable
9.9.3 CR_LAMPCONSTTAR Command
Command
"CR_LAMPCONSTTAR" [CR]
Details
Get value of Target for Constant mode
Acceptable
Response
%1
Unacceptable
9.9.4 CR_LAMPCONSTCUR Command
Command
"CR_LAMPCONSTCUR" [CR]
Details
Get value of Current for Constant mode
Acceptable
Response
%1
Unacceptable
"000_%1" [CR]
"2**"
2 ---------------- indicates 2 lamps are used in this model.
* ---------------- indicates the status of each lamp in lamp number
order.
"Y" means the lamp operating time is over the
threshold for lamp replacement, and "N" means
it has not reached to.
e.g.
"2YN" ------------ This indicates it is 2-lamp system, and Lamp #2
has not been reached to the replacement time
while #1 should be replaced.
"?" [CR]
"000_%1" [CR]
"2LAMP" ------------- Lamp mode is set to 2-Lamps
"1LAMPAUTO" --- Lamp mode is set to 1-Lamp (Auto) and
automatically and preferentially uses a lamp
with shorter cumulated lighting time
"1LAMP1" ----------- Lamp mode is set to 1-Lamp (LAMP1)
"1LAMP2" ----------- Lamp mode is set to 1-Lamp (LAMP2)
"CONSTANT" ------ Lamp mode is set to Constant mode.
"Error Code" [CR]
"000_%1" [CR]
"0000"-"1024"
"Error Code" [CR]
"000_%1" [CR]
"0000"-"1024"
"Error Code" [CR]
83/105