PLC-HF10000L Expand Serial Command Functional Specifications
8.9.57 CF_KEYDIS Command
Command
"CF_KEYDIS_%1" [CR]
"NONE" ------------------------- RC & KEY are valid
%1
"RC" ----------------------------- RC is invalid
"KEY" --------------------------- KEY is invalid
Details
Set the limitation of RC/KEY use (Valid only when in the normal Power ON status)
Acceptable
Response
Unacceptable
8.9.58 CF_SHUTRCPROT Command
Command
"CF_SHUTRCPROT_%1" [CR]
"ON" ------------------ Disable RC key from controlling Shutter (Protection On)
%1
"OFF" ----------------- Enable RC key to control Shutter (Protection Off)
Set valid / invalid of RC use on Shutter control function
Details
(Valid only when in the normal Power ON status)
Acceptable
Response
Unacceptable
8.9.59 CF_SHUTKEYPROT Command
Command
"CF_SHUTKEYPROT_%1" [CR]
"ON" --------- Disable key on the side panel from controlling Shutter (Protection On)
%1
"OFF" -------- Enable key on the side panel to control Shutter (Protection Off)
Set valid / invalid use of key on the top panel on Shutter control function.
Details
(Valid only when in the normal Power ON status)
Acceptable
Response
Unacceptable
8.9.60 CF_SHUTH Command
Command
"CF_SHUTH_%1" [CR]
"005"-"480"----------Specify setting time directly
%1
"UP" ------------------ Add 1 minute
"DN" ------------------Decrease 1 minute
Set time of operating shutter management function.
(Valid only when in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]