PLV-WF20 Expand Serial Command Functional Specifications
9.9 Lamp Status Read Commands
9.9.1 CR_LAMPREPL Command
Command
"CR_LAMPREPL" [CR]
Details
Get the information of Lamp Replacement time
Acceptable
Response
Unacceptable
9.9.2 CR_LAMPMODE Command
Command
"CR_LAMPMODE" [CR]
Details
Get Lamp mode setting status
Acceptable
Response
Unacceptable
9.9.3 CR_AUTOLAMPCONTRL Command
Command
"CR_AUTOLAMPCONTRL" [CR]
Details
Get selected Lamp control mode
Acceptable
Response
Unacceptable
9.9.4 CR_LAMPSTS Command
Command
"CR_LAMPSTS" [CR]
Details
Get the information of Lamp lighting status
Acceptable
Response
Unacceptable
"000_%1" [CR]
"2**"
2 ---------------- indicates 2 lamps are used in this model.
* ---------------- indicates the status of each lamp in lamp number
%1
e.g.
"2YN" ------------ This indicates it is 2-lamp system, and Lamp #2
"?" [CR]
"000_%1" [CR]
"FULL" ---------------- Lamp mode is set to 4-lamp (FULL)
%1
"HALF" ---------------- Lamp mode is set to 2-lamp (HALF)
"?" [CR]
"000_%1" [CR]
"NORMAL" ---------- NORMAL is selected.
%1
"ECO" ---------------- ECO is selected.
"AUTO" -------------- AUTO is selected.
"Error Code" [CR]
"000_%1" [CR]
"2**"
The first character indicates 2 lamps are used in this model.
The following characters indicate each lamp status in lamp
number order as showed below.
"I" ------------------------ Lamp is ON
%1
"O" ---------------------- Lamp is OFF
"X" ----------------------- Lamp Failure
e.g.
"2IO" ------------------- This indicates it is 2-lamps system, Lamp
#1 is ON, and #2 is OFF.
"?" [CR]
order.
"Y" means the lamp operating time is over the
threshold for lamp replacement, and "N" means
it has not reached to.
has not been reached to the replacement time
while #1 should be replaced.
56/68