Cr_Cmtgxy_%1 Command; Cr_Cmtgg_%1 Command; Cr_Cmautotestpat Command; Cr_Cmmstestpat Command - Sanyo PLC-HF10000L - 10000 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-HF10000L - 10000 Lumens:
Table of Contents

Advertisement

PLC-HF10000L Expand Serial Command Functional Specifications

9.10.47 CR_CMTGXY_%1 Command

Command
"CR_CMMTGXY_%1" [CR]
Details
Get "x""y" value of Target of Color matching
Acceptable
%1
Response
%2
%3
Unacceptable

9.10.48 CR_CMTGG_%1 Command

Command
"CR_CMMTGG_%1" [CR]
Details
Get "g" value of Target of Color matching
Acceptable
%1
Response
%2
Unacceptable

9.10.49 CR_CMAUTOTESTPAT Command

Command
"CR_CMAUTOTESTPAT" [CR]
Details
Get setting status of Auto test pattern of Color matching
Acceptable
Response
%1
Unacceptable

9.10.50 CR_CMMSTESTPAT Command

Command
"CR_CMMSTESTPAT" [CR]
Details
Get setting status of Test pattern(Measured) of Color matching
Acceptable
Response
%1
Unacceptable
"000_%2" [CR]
"RED" ---------------------- value of Red is selected
"GREEN" ----------------- value of Green is selected
"BLUE" -------------------- value of Blue is selected
"WHITE" ------------------ value of White is selected
"CYAN" -------------------- value of Cyan is selected
"MAGENTA" ------------- value of Magenta is selected
"YELLOW" --------------- value of Yellow is selected
"0000"-"1000"------------ "x" value of color of %1
"0000"-"1000"------------ "y" value of color of %1
"Error Code" [CR]
"000_%2" [CR]
"RED" ---------------------- value of Red is selected
"GREEN" ----------------- value of Green is selected
"BLUE" -------------------- value of Blue is selected
"WHITE" ------------------ value of White is selected
"CYAN" -------------------- value of Cyan is selected
"MAGENTA" ------------- value of Magenta is selected
"YELLOW" --------------- value of Yellow is selected
"0000"-"1000"------------ "g" value of color of %1
"Error Code" [CR]
"000_%1" [CR]
"ON" ---------------------- On is selected
"OFF" --------------------- Off is selected
"Error Code" [CR]
"000_%1" [CR]
"RED" ---------------------- Red is displayed
"GREEN" ----------------- Green is displayed
"BLUE" -------------------- Blue is displayed
"OFF" -----------------------Test pattern display is not displayed
"Error Code" [CR]