PLC-HF10000L Expand Serial Command Functional Specifications

8.9.48 CF_PJPINCODE Command

Command
"CF_PJPINCODE_%1" [CR]
%1
"0000 – 9999" ------------- Directly specify PJ PIN code
Enter PIN code to cancel PIN code lock
(Available only in the normal Power ON status)
PIN code can not be changed. (Only PIN code lock is canceled.)
*When PIN code Lock is enabled:
PIN code is matched ------------------------- Command is valid (Acceptable)
PIN code is mismatched -------------------- Command is invalid (Error code "102")
PIN code is beyond %1 available range ----- Command is invalid (Error code "?")
Details
When PIN code lock is canceled:
PIN code is within %1 range ----------- Command is valid (Acceptable)
PIN code is out of %1 range ----------- Command is invalid (Error code is "?")
This command is only valid when "PJ PIN code" dialog is displayed to enter PIN
code after Power is ON and Countdown is completed.
When PIN code lock is set to "On1", it needs to send this command every time the
projector is turned on.
Acceptable
Response
Unacceptable

8.9.49 CF_FILH Command

Command
"CF_FILH_%1" [CR]
%1
"RST" ---------------------- Reset Filter used time
Details
Reset used time for filter of projector
Acceptable
Response
Unacceptable

8.9.50 CF_FILTIMER Command

Command
"CF_FILTIMER_%1" [CR]
"00400" ---------------------- Set 400 hours
"00700" ---------------------- Set 700 hours
%1
"01000" ---------------------- Set 1000 hours
"OFF" ---------------------- Set Off(Do not warning display)
Details
Set time to display Filter cleaning / replacement warning on screen
Acceptable
Response
Unacceptable

8.9.51 CF_PTIMER Command

Command
"CF_PTIMER_%1" [CR]
"START" -------------------------- Start P-timer
"STOP" ---------------------------- Stop P-timer
%1
"RESTART" ---------------------- Resume P-timer
"RST" ------------------------------ Reset P-timer
"EXIT" ----------------------------- Exit P-timer function
Select the status of P-timer.
Details
(Available only in the normal Power ON status)
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
57/105