PLC-HF10000L Expand Serial Command Functional Specifications

10.2.2. When the command pipelining is needed

When it needs command pipelining, the operation is the same as the remote control as
below:
1)
Sending-side system issues commands every 100ms
2)
When receiving an applicable command, the function is executed repeatedly for
120ms.
3)
When receiving the same command in a row within 120ms, the function is repeatedly
executed for another 120ms from the moment of the second command reception.
4)
When there is no incoming command after 120ms, the execution of pipelining is
stopped.
5)
When the projector receives other command within 120ms, the execution of pipelining
is stopped.

10.3. Status Read Command with Address

10.3.1. Format

1) PC issues a command in the format as below:
"A" Address "CR" Command [CR]
"A" Address "CR_" Command [CR]
Address: 3-digit number ("001" – "999")
Command: string (Refer to Basic and Expand Serial Commands)
2) The only projectors that have the address matching with the one in the received data
decode the command, and it returns required data.
Required Data [CR]
Required Data: String (Refer to Basic Status Read Commands)
3) When the received data cannot be decoded, it returns "? " [CR]
or
105/105