Cf_Disp Command; Cf_Backgnd Command; Cf_Pip Command; Cf_Pipmode Command - Sanyo PLC-HF10000L - 10000 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-HF10000L - 10000 Lumens:
Table of Contents

Advertisement

PLC-HF10000L Expand Serial Command Functional Specifications

8.9.4 CF_DISP Command

Command
"CF_DISP_%1" [CR]
"ON" ----------------------------- Set Display to ON
"CNTDWNOFF" -------------- Set Display to Count down Off
%1
"OFF" --------------------------- Set Display to OFF
"UP" ----------- The same operation as pressing Up key or Left key
"DN" -----------The same operation as pressing Down key or Right key
Set/Cancel Display. (Valid only when in the normal Power ON status.)
Details
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable

8.9.5 CF_BACKGND Command

Command
"CF_BACKGND_%1" [CR]
"BLUE" -------------------- Select Blue Back
"USER" ------------------- Select User
%1
"BLACK" ------------------ Select Black Back
"UP" ----------- The same operation as pressing Up key or Left key
"DN" -----------The same operation as pressing Down key or Right key
Set Screen status for no signal.(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and the setting remains
Details
even after the power is turned to ALL OFF status.
*When ÿ 1="USER" is received, error code "101" is returned, in the case of
Capture non-practice.
Acceptable
Response
Unacceptable

8.9.6 CF_PIP Command

Command
"CF_PIP_%1" [CR]
"OFF" -------------------- Select Off
"USER1" ---------------- Select User1
"USER2" ---------------- Select User2
%1
"USER3" ---------------- Select User3
"USER4" ---------------- Select User4
"USER5" ---------------- Select User5
Set "Picture in Picture" status.(Available only in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and the setting remains
even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable

8.9.7 CF_PIPMODE Command

Command
"CF_PIPMODE_%1" [CR]
"PINP" -------------------- Select P in P mode
%1
"PBYP" ------------------- Select P by P mode
Details
Set mode of" Picture in Picture". (Available only in the normal Power ON status)
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
44/105

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-hf10000l

Table of Contents