PLC-HF10000L Expand Serial Command Functional Specifications
9.10.22 CR_KEYDIS Command
Command
"CR_KEYDIS" [CR]
Details
Get setting status of RC/KEY use limitation (valid or invalid)
Acceptable
Response
%1
Unacceptable
9.10.23 CR_SHUTRCPROT Command
Command
"CR_SHUTRCPROT" [CR]
Details
Get status if Shutter can be controlled by R/C
Acceptable
Response
%1
Unacceptable
9.10.24 CR_SHUTKEYPROT Command
Command
"CR_SHUTKEYPROT" [CR]
Details
Get status if Shutter can be controlled by key on the side panel
Acceptable
Response
%1
Unacceptable
9.10.25 CR_SHUTH Command
Command
"CR_SHUTH" [CR]
Details
Get time setting to start the shutter management
Acceptable
Response
%1
Unacceptable
9.10.26 CR_SHUTEFFECT Command
Command
"CR_SHUTEFFECT" [CR]
Details
Get status of Shutter effect function.
Acceptable
Response
%1
Unacceptable
"000_%1" [CR]
"NONE" ------------------------- RC & KEY are valid
"RC" ----------------------------- RC is invalid
"KEY" --------------------------- KEY is invalid
"?" [CR]
"000_%1" [CR]
"ON" -------------------- Shutter is not controllable by R/C
"OFF" ------------------- Shutter is controllable by R/C
"?" [CR]
"000_%1" [CR]
"ON" ----------- Shutter is not controllable by key on the side panel
"OFF" ---------- Shutter is controllable by key on the side panel
"?" [CR]
"000_%1" [CR]
"005" -------------------- 5 minutes
"006" -------------------- 6 minutes
:
"479" -------------------- 479 minutes
"480" -------------------- 480 minutes
"?" [CR]
"000_%1" [CR]
"OFF" --------Fade in / out function is set to Off.
"L1" --------- Fade in / out function is set to L1.
"L2" --------- Fade in / out function is set to L2.
"Error Code" [CR]