Lamp Command; Cf_Lampmode Command; Cf_ Lampconsttar Command; Cf_Autolampcontrl Command - Sanyo PLC-HF10000L - 10000 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-HF10000L - 10000 Lumens:
Table of Contents

Advertisement

PLC-HF10000L Expand Serial Command Functional Specifications

8.8 Lamp Command

8.8.1 CF_LAMPMODE Command

Command
"CF_LAMPMODE_%1" [CR]
"2LAMP" --------------- Set lamp mode to 2-lamps
"1LAMPAUTO" ------ Set lamp mode to 1-lamp and automatically and preferentially
"1LAMP1" ------------ Set lamp mode to 1-lamp (LAMP1)
%1
"1LAMP2" ------------ Set lamp mode to 1-lamp (LAMP2)
"CONSTANT" ------ Set lamp mode to Constant mode, and automatically switch
Select Lamp mode. (Valid only when in the normal Power ON status.)
Details
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable

8.8.2 CF_ LAMPCONSTTAR Command

Command
"CF_LAMPCONSTTAR_%1" [CR]
%1
"0000" - "1024"
Set Target value for Constant mode of Lamp mode.
(Valid only when in the normal Power ON status.)
Details
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable

8.8.3 CF_AUTOLAMPCONTRL Command

Command
"CF_AUTOLAMPCONTRL_%1" [CR]
"NORMAL" ------------------------ Set Lamp status to Normal mode
"ECO1" ------------------------------- Set Lamp status to Eco1 mode
%1
"ECO2" ------------------------------- Set Lamp status to Eco2 mode
"AUTO" ----------------------------- Set Lamp status to Auto mode
Select Lamp control mode. (Valid only when in the normal Power ON status.)
Details
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable

8.8.4 CF_LAMPLIFECONTRL Command

Command
"CF_LAMPLIFECONTRL_%1" [CR]
"MODE1" -------------------------- Set Lamp life control mode to Mode1
%1
"MODE2" -------------------------- Set Lamp life control mode to Mode2
Select Lamp life control. (Valid only when in the normal Power ON status.)
Details
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
use a lamp with shorter cumulated lighting time.
between 2-Lamps mode and 1-Lamp mode, and/or modulate
the light to keep the target brightness
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
41/105

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-hf10000l

Table of Contents