Clear Threshold Alert(S) Dialog Box - HP 316095-B21 - StorageWorks Edge Switch 2/24 User Manual

Edge switch 2/24 product manager user guide
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Detached WWN: Click the radio button and enter a world wide name (WWN) in
the proper format (xx.xx.xx.xx.xx.xx.xx.xx) or a nickname configured through the
Product or HAFM applications. The device with this WWN or nickname will have
exclusive communication privileges through the port if Port Binding is enabled.
Note the following:
— If you do not enter valid WWN or nickname in this field, but the Port
Binding check box is checked (enabled), then no devices can communicate
through the port.
— If you enter a WWN or nickname in this field and do not place a check in the
Port Binding check box, the WWN or nickname will be stored, and all
devices can communicate through the port.
Activate: Click this button to activate settings in this dialog box.
Warning and error message display:
If one or more of the nodes logged into the port does not match the WWN or
nickname configured in the field by the WWN radio button, a warning dialog box
displays after you activate the configuration. This warning box displays a list of all
nodes that will be logged off if you continue. If you click Continue on the
warning box, these nodes will be logged off and the port can only communicate
with the device with the WWN or nickname configured in the WWN field.
An error message displays after you activate the configuration if the format for the
WWN entered in the WWN field is not valid (not in xx.xx.xx.xx.xx.xx.xx.xx
format) or if you have entered a nickname that was not configured through the
Product Manager.
Clear Threshold Alert(s)
Click this to display the Clear Threshold Alert(s) dialog box. Select the appropriate
option to clear alerts for the selected port only or all ports on the switch. This clears all
attention indicators that notify users of threshold alerts in dialog boxes and views.
This action also restarts the notification interval and the cumulative minutes for
utilization % interval.
Figure 2–10: Clear Threshold Alert(s) dialog box
edge switch 2/24 product manager user guide
Monitoring and Managing the Switch
2–19

Advertisement

Table of Contents