v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 7996," on page 11 to determine which components are CRUs and which
components are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
1801
No more ROM available.
1802
No more I/O space available.
1803
No more extended memory.
Action
1. Run the Configuration/Setup Utility program and
make sure that ROM resource settings are
correct.
2. Remove each I/O-expansion card one at a time,
restarting the blade workstation each time, until
the problem is isolated.
3. Replace the following components one at a time,
in the order shown, restarting the blade
workstation each time:
a. Failed I/O-expansion card
b. (Trained service technician only) System
board assembly
1. Run the Configuration/Setup Utility program and
make sure that I/O resource settings are correct.
2. Remove each I/O-expansion card one at a time,
restarting the blade workstation each time, until
the problem is isolated.
3. Replace the following components one at a time,
in the order shown, restarting the blade
workstation each time:
a. Failed I/O-expansion card
b. (Trained service technician only) System
board assembly
1. Run the Configuration/Setup Utility program and
make sure that extended memory settings are
correct.
2. Remove each I/O-expansion card one at a time,
restarting the blade workstation each time, until
the problem is isolated.
3. Replace the following components one at a time,
in the order shown, restarting the blade
workstation each time:
a. Failed I/O-expansion card
b. (Trained service technician only) System
board assembly
47