Statement 2:
CAUTION:
When replacing the lithium battery, use only IBM Part Number 15F8409 or an
equivalent type battery recommended by the manufacturer. If your system has
a module containing a lithium battery, replace it only with the same module
type made by the same manufacturer. The battery contains lithium and can
explode if not properly used, handled, or disposed of.
Do not:
v Throw or immerse into water
v Heat to more than 100°C (212°F)
v Repair or disassemble
Dispose of the battery as required by local ordinances or regulations.
Note: See "Battery return program" on page 89 for more information.
To install the battery, complete the following steps.
1. Follow any special handling and installation instructions that come with the
battery.
2. Insert the battery:
a. Tilt the battery so that you can insert it into the socket on the side opposite
the battery clip.
b. Press the battery down into the socket until it clicks into place. Make sure
the battery clip holds the battery securely.
3. Install the blade workstation cover (see "Installing the blade workstation cover"
on page 20).
4. Install the blade workstation into the BladeCenter unit (see "Installing the blade
workstation in a BladeCenter unit" on page 17).
5. Turn on the blade workstation and run the Configuration/Setup Utility program.
Set configuration parameters as needed (see "Using the Configuration/Setup
Utility program" on page 9 for information).
Chapter 4. Removing and replacing blade workstation components
31