Figure 56. Replacing The Battery - Intel TIGI2U - Carrier Grade Server User Manual

Carrier grade server
Hide thumbs Also See for TIGI2U - Carrier Grade Server:
Table of Contents

Advertisement

Platform Installations and Upgrades
1. Power down the server system and unplug all peripheral devices and the AC power
cable or the DC mains.
2. Remove the chassis cover. For instructions, see
3. Locate the battery.
4. Insert the tip of a small flat bladed screwdriver, or an equivalent, under the tab in the
plastic retainer. Gently push down on the screwdriver to lift the battery.
5. Remove the battery from its socket.
6. Dispose of the battery according to local ordinance.
7. Remove the new lithium battery from its package, and, being careful to observe the
correct polarity, insert it in the battery socket.
8. Close the chassis.
9. Run Setup to restore the configuration settings to the RTC.
78

Figure 56. Replacing the Battery

"Removing the Chassis Cover."
®
Intel
Carrier Grade Server TIGI2U User Guide

Advertisement

Table of Contents
loading

Table of Contents