Environmental Specifications; System Level Environmental Limits; Serviceability And Availability; Replacing The Backup Battery - Intel SR2612UR Product Specification

Hide thumbs Also See for SR2612UR:
Table of Contents

Advertisement

Intel® Server System SR2612UR TPS
9.

Environmental Specifications

9.1

System Level Environmental Limits

The following table defines the system level operating and non-operating environmental limits.
Parameter
Operating Temperature
Non-Operating
Temperature
Non-Operating Humidity
Acoustic noise
Shock, operating
Shock, unpackaged
Shock, packaged
Vibration, unpackaged
ESD
System Cooling
Requirement in BTU/Hr
9.2

Serviceability and Availability

The system is designed to be serviced by qualified technical personnel only.
The desired Mean Time To Repair (MTTR) of the system is 30 minutes, which includes
diagnosing the system problem. To meet this goal, the system enclosure and hardware were
designed to minimize the MTTR.
The following table defines the maximum time needed by a trained field service technician to
perform the listed system maintenance procedures after diagnosing the system and identifying
the failed component.
Remove cover
Remove and replace hard disk drive
Remove and replace power supply module
Remove and replace system fan
Remove and replace backplane board
Remove and replace control panel module
Remove and replace server board
9.3

Replacing the Backup Battery

The lithium battery on the server board powers the real time clock (RTC) for up to 10 years in
the absence of power. When the battery starts to weaken, it loses voltage, and the server
settings stored in CMOS RAM in the RTC (e.g., the date and time) may be wrong. Contact your
customer service representative or dealer for a list of approved devices.
Revision 1.3

Table 31. System Environmental Limits Summary

+10° C to +35° C with the maximum rate of change not to exceed 10°C per hour
-40° C to +70° C
90%, non-condensing at 35° C
Sound power: 7.0 BA in an idle state at typical office ambient temperature. (23
+/- 2° C)
Half sine, 2 g peak, 11 milliseconds
Trapezoidal, 25 g, velocity change 136 inches/second (≧40 lbs to < 80 lbs)
Non-palletized free fall in height 24 inches (≧40 lbs to < 80 lbs)
5 Hz to 500 Hz, 2.20 g RMS random
+/-15 KV except I/O port +/- 8 KV per Intel
2550 BTU/hour

Table 32. Time Estimate for System Maintenance Procedures

Activity
Intel order number E76293-003
Environmental Specifications
Limits
®
Environmental test specification
Time Estimate (Minutes)
1
2
1
3
9
2
11
49

Advertisement