Server Platform Features

Front Panel IO (FPIO) System Board

Features

The TIGI2U server system has the following FPIO features:
Four switches to control power-on, reset, NMI, and the system ID LED
One system ID LED that can be controlled remotely or by the system ID switch
Two system activity LEDs that indicate power-on and NIC activity
Two hard drive activity/fault LEDS that indicate activity/fault status for drives 1 and 2
Four system fault LEDs that indicate critical, major, minor, and power system fault
status
Four system fault relays for external critical, major, minor, and power fault indicators
One SCSI bus with hot-swap circuitry for controlling hot-swap SCSI disk drives 1 and 2
IDE Bus from IDE Connector to blind mate connector
One blind mate connector for interfacing to CDROM or floppy drive carrier assembly
Connectors for interfacing to the power supply, server baseboard, drive carrier
assemblies, and hot plug disk drives 1 and 2

FPIO SCSI Subsystem Status LEDs

The status LEDs give the user a visual indication of the drives' condition. There is a single
LED for each drive. The LEDs are bi-colored and use a combination of color and blinking
frequency to indicate multiple conditions. The LEDs are mounted on the FPIO board, and
the light is directed to the front panel through the use of a light pipe assembly. See Table
4 for LED activity definitions. See the Firmware EPS for definitions of the different blink
rates.
LED State
Solid Green
Blinking Green
Blinking
Yellow/Green
Blinking
Yellow/Blank
Blank
®
Intel
Carrier Grade Server TIGI2U User Guide
Table 4.
LED Activity Definitions
Drive Active
X
Fault Condition
X
X
25