Server Platform Features

Power Supply

The power supply cage supports up to two hot-swap power supplies (either AC input or
DC input) in a (1+1) redundant configuration. A power supply filler module for the empty
power supply site is supplied for systems without redundancy. Only the DC input version
is NEBS certified.
The power subsystem supports the implementation of remote management features
including remote enable, which permits power to be activated from a variety of sources.
The power supply is rated for 600 watts of power at the following voltages.
PARAMETER
DC Voltage
PARAMETER
MIN
Line Voltage
90V
rms
(110)
Line Voltage
180V
(220)
Frequency
47 Hz
Notes:
1. Maximum input current at low input voltage range shall be measured at 90Vac,
at max load.
2. Maximum input current at high input voltage range shall be measured at
180VAC, at max load.
3. This is not to be used for determining agency input current markings.
4. Maximum rated input current is measured at 100VAC and 200VAC
®
Intel
Carrier Grade Server TIGI2U User Guide
MIN
-38 VDC
-48VDC/-60VDC
RATED
100-127 V
140V
rms
200-240 V
264V
rms
rms
50/60Hz
63 Hz
DC Power Supply:
RATED
MAX
-75VDC
AC Power Supply:
Start-up
MAX
Vac
85Vac
75Vac
rms
±4Vac
±5Vac
-
-
rms
Max Input Current
20.5ADC
Power
Max Input
Off
AC Current
Vac
10.0
1,3
A
rms
2,3
5.0 A
rms
Max Rated
Input AC
Current
4
8.9A
rms
4
4.5A
rms
27