Removing The Processor; Figure 17. Removing Heat Sink - Intel TIGI2U - Carrier Grade Server User Manual

Carrier grade server
Hide thumbs Also See for TIGI2U - Carrier Grade Server:
Table of Contents

Advertisement

Platform Installations and Upgrades

Removing the Processor

1. Power down the server system and unplug all peripheral devices and the AC power
cable or the DC mains.
2. Remove the chassis cover. For instructions, see
3. Remove the processor air duct that covers the processor. For instructions, see
"Removing the Processor Air
4. Loosen the four captive screws on the corners of the heat sink.
5. Twist the heat sink slightly to break the seal between the heat sink and the processor.
6. Lift the heat sink from the processor. If it does not pull up easily, twist the heat sink
again. Do not force the heat sink from the processor. Doing so could damage the
processor.
7. Lift the processor lever.
8. Remove the processor.
®
Intel
Carrier Grade Server TIGI2U User Guide
Duct."

Figure 17. Removing Heat Sink

"Removing the Chassis
Cover."
43

Advertisement

Table of Contents
loading