SYMPTOM
Unit "hangs" (won't
respond to top panel)
whenever a particular
Program, Mix, or Bank is
accessed
Mod wheel doesn't work as
expected.
A
A6 R
NDROMEDA
EFERENCE
CAUSE
Corrupted data in
memory.
Mod wheel wasn't in
lowest position when the
unit was reinitialized.
M
ANUAL
Appendix C: Troubleshooting
SOLUTION
Replace an individual
Program or Mix by a SysEx
dump or the COPY feature
in STORE mode.
If the entire User bank is
corrupted, turn the unit on
while pressing soft button
3. This erases the contents
of the User bank and
reinitializes the Global
parameters as well.
If a Preset bank is
corrupted, press STORE
and use the COPY feature
to overwrite the entire
bank with a non-corrupted
bank. Banks are also
available on the Alesis web
site.
Reinitialize the unit (turn
on while holding down
soft button 4) with the mod
wheel in its full down
position.