Alesis ANDROMEDA A6 Reference Manual page 163

16-voice real analog synthesizer
Hide thumbs Also See for ANDROMEDA A6:
Table of Contents

Advertisement

how we use the the term stage. It refers to the same envelope parameters as before,
but when describing the loop start function, the loop starts at the beginning of the
selected stage only. For example, you cannot start a loop during the Attack stage's
rise time, only at the point where the Attack stage starts.
By the same token, for a loop's end functions, the loop finishes at the completion of
the last stage before the loop end stage. For example, you cannot end a loop at some
point during the Decay 2 stage's fall time, only at the point where the Decay 2 stage
is completed.
DISPLAY
PAGE
PANEL LABEL
LOOP
LOOP
button
A
A6 R
NDROMEDA
PARAMETER
DISPLAY
As you select and adjust the Loop parameters below, note how the display
changes to reflect your settings. The box will change size and position with
new
and
START
END
curve.
START
END
COUNT
This parameter determines how many times the selected
envelope will loop.
M
EFERENCE
ANUAL
Chapter 6: Modulation and Envelopes
OPTIONS
or RANGE DESCRIPTION
points and will display a representation of the selected
DEL Delay
This parameter is used to select the stage in the
envelope where the loop begins.
ATK Attack
The loop will cycle through the envelope's
D1 Decay 1
stages that are between what you select as the
and
START
D2 Decay 2
the
START
stage to be
SUS Sustain
be
, the envelope will repeat
D2
The number times the loop cycles or repeats is
selected by the
the next page.
ATK Attack
This parameter actually performs two
functions:
D1 Decay 1
1. As its name implies, this is the stage in the
D2 Decay 2
envelope where the loop ends. If the loop
repeats, this is also the stage where the
SUS Sustain
loop returns to the loop's
R1 Release 1
2. This is also the stage in the envelope
where the loop gets its initial instruction
to start looping and begins a smoothed
transition to the Loop Start stage. The
transition is an amount of time that is set
by the
So when setting this parameter, keep in mind
that this is the stage in the envelope where the
loop receives both its command to start and its
command to return to the first stage in the
loop after each loop cycle.
1 ··· 240
This selects a specific number of loop cycles
up to 240. After the last cycle is completed, the
envelope is released.
stages. For example, if you set
END
ATK
and the
END
ATK
D1
D2
parameter, described on
COUNT
START
and
parameters.
SMOOTH
SSHAPE
stage to
stage.
161

Advertisement

Table of Contents
loading

This manual is also suitable for:

A6 andromeda

Table of Contents