Novell ZENWORKS LINUX MANAGEMENT 7.3 IR2 - INSTALLATION GUIDE 07-20-2009 Installation Manual page 116

Hide thumbs Also See for ZENWORKS LINUX MANAGEMENT 7.3 IR2 - INSTALLATION GUIDE 07-20-2009:
Table of Contents

Advertisement

6 Click Add to display the Select Bundles dialog box.
7 Navigate to and click the desired upgrade bundle to move it to the Selected list, then click OK.
8 Click Next to display the Catalog Assignments page.
9 Click Add, navigate to and click the desired devices to move them to the Selected list, then click
OK to display the Bundles Options page.
10 Click Next to display the Finish page, review the information, then click Finish.
11 Depending on your needs, continue with
and SLED 10 by Using an Upgrade Bundle" on page 116
Managed Devices by Using an Upgrade Bundle" on page
Upgrading Managed Devices Other Than SLES 10 and SLED 10 by Using an Upgrade
Bundle
1 In ZENworks Control Center, click the Policies tab.
2 Click New, then click Policy to display the Policy Type page.
3 Select Remote Execute Policy, then click Next to display the Policy Name page.
4 Specify a name for the policy, then click Next to display the Remote Execute Policy page.
5 From the Script to run drop-down list, choose Define your own script.
6 Paste the contents of the
script file from the mount point
The Policy script performs the following tasks:
Subscribes to the catalog containing the upgrade bundle.
Installs the upgrade bundle on the managed device.
7 Edit the script so that
Upgrade Bundles
(Step 7 on page
8 Click Next to display the Summary page, then click Next to display the Policy Assignments
page.
9 Click Add to display the Select Assignments dialog box, browse to and select the devices to
which you want to assign the Remote Execute policy, then click OK.
10 Click Next to display the Policy Schedule page.
11 In the Schedule Type drop-down list, select Date Specific, specify a start date and time to apply
the policy, then click Next to display the Policy Groups page.
NOTE: If you want to verify the upgrade immediately, set the start date to today and the start
time to 12 a.m. The Remote Execute policy is executed at the next scheduled refresh for the
devices. Alternately, you can manually refresh the devices.
12 Click Next to display the Finish page, then click Finish.
The Remote Execute policy is enforced as scheduled, after the managed devices' next
scheduled refresh. If the time you specified in
the policy is enforced on the next refresh.
116 Novell ZENworks 7.3 Linux Management Installation Guide
script file into the Script content box. You can access the
policy.sh
directory.
/data
is the catalog you created in
catalog_name
and
is the bundle that you specified while creating the catalog
bundle
116).
"Upgrading Managed Devices Other Than SLES 10
or
"Upgrading SLES 10 or SLED 10
117.
Step 11
occurs before the next scheduled refresh,
Creating Catalogs for

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zenworks linux management 7.3 ir2

Table of Contents