Diagnostic Output And Beep Codes Looped On Post - NEC POWERMATE 4100M Service Manual

Hide thumbs Also See for POWERMATE 4100M:
Table of Contents

Advertisement

4-12
Maintenance and Troubleshooting
Table Section 4-5 lists codes that are reported via the diagnostic port and the speaker only
if MANLOOP EQU TRUE and the "manufacturing jumper" indicates loop on POST. Oth-
erwise, these errors are reported via the screen and POST continues. Use of the manufac-
turing jumper requires working correctly configured CMOS.
Table Section 4-5 Diagnostic Output and Beep Codes Looped on POST
Diagnostic Port Output
E_TIMRI
EQU 34h
E_SHUTD
EQU 35h
E_GTA20
EQU 36h
E_PMUXI
EQU 37h
E_BAMEM
EQU 38h
E_TIMR2
EQU 3Ah
E_TODCK
EQU 3Bh
E_SRLPT
EQU 3Ch
E_PRLPT
EQU 3Dh
E_80287
EQU 3Eh
Beep Codes
Description of Test or Failure
4-2-1
Timer tick interrupt test in progress or failure
4-2-2
Shutdown test in progress or failure
4-2-3
Gate A20 failure
4-2-4
Unexpected interrupt in protected mode
4-3-1
RAM test in progress or failure above address
0FFFFh
4-3-3
Interval timer channel 2 test in progress or failure
4-3-4
Time-of-Day clock test in progress or failure
4-4-1
Serial port test in progress or failure
4-4-2
Parallel port test in progress or failure
4-4-3
Math coprocessor test in progress or failure