ZyXEL Communications NWA3000-N Series User Manual page 293

Wireless n business wlan 3000 series access point
Hide thumbs Also See for NWA3000-N Series:
Table of Contents

Advertisement

Table 102 Device HA Logs (continued)
LOG MESSAGE
Master configuration
is the same with
Backup. Skip updating
it.
%s file not existed,
Skip syncing it for %s
Master firmware
version can not be
recognized. Stop
syncing from Master.
Device HA Sync has
failed when syncing %s
for %s due to bad
\"Sync Password\".
Device HA Sync has
failed when syncing %s
for %s due to bad
\"Sync From\" or
\"Sync Port\".
Device HA Sync has
failed when syncing %s
for %s.
Sync Failed: Cannot
connect to Master when
syncing %s for %s.
Backup firmware
version can not be
recognized. Stop
syncing from Master.
Sync failed: Remote
Firmware Version
Unknown
Master firmware
version should be the
same with Backup.
Update %s for %s has
failed.
Update %s for %s has
failed: %s.
NWA3000-N Series User's Guide
DESCRIPTION
The System Startup configuration file synchronized from the
Master is the same with the one in the Backup, so the
configuration does not have to be updated.
There is no file to be synchronized from the Master when
syncing a object (AV/AS/IDP/Certificate/System
Configuration), But in fact, there should be something in the
Master for the device to synchronize with, 1st %s: The
syncing object, 2ed %s: The feature name for the syncing
object.
Synchronizing stopped because the firmware version file was
not found in the Master. A Backup device only synchronizes
from the Master if the firmware versions are the same
between the Master and the Backup.
The synchronization password was incorrect when attempting
to synchronize a certain object (AV/AS/IDP/Certificate/
System Configuration).
1st %s: The object to be synchronized, 2ed %s: The feature
name for the object to be synchronized.
The Sync From IP address or Sync Port may be incorrect
when synchronizing a certain object (AV/AS/IDP/Certificate/
System Configuration).
Synchronization failed when synchronizing a certain object
(AV/AS/IDP/Certificate/System Configuration) due to an
unknown reason, 1st %s: The object to be synchronized, 2ed
%s: The feature name for the object to be synchronized.
Synchronization failed because the Backup could not connect
to the Master. The object to be synchronized, 2ed %s: The
feature name for the object to be synchronized.
The firmware version on the Backup cannot be resolved to
check if it is the same as on the Master. A Backup device only
synchronizes from the Master if the Master and the Backup
have the same firmware versions.
The firmware version on the Master cannot be resolved to
check if it is the same as on the Master. A Backup device only
synchronizes from the Master if the Master and the Backup
have the same firmware versions.
The Backup and Master have different firmware versions. A
Backup device only synchronizes from the Master if the
Master and the Backup have the same firmware versions.
Updating a certain object failed when updating (AS/AV/IDP/
Certificate/System Configuration). 1st %s: The object to be
synchronized, 2ed %s: The feature name for the object to be
synchronized.
Updating a certain object failed when updating (AS/AV/IDP/
Certificate/System Configuration) due to some reason. 1st
%s: The object to be synchronized, 2ed %s: The feature
name for the object to be synchronized.
Appendix A Log Descriptions
293

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nwa-3160Nwa3160-n

Table of Contents