Section5

Using the Multi-Task Function

Using the Multi-Task Function

In the ZS-HLDC Series, you can set multiple measurement processing for one sensing
condition. This measurement processing is called a "task."
• Application example: Measure the height and surface fluctuation simultaneously.
Measuring Multiple Items Simultaneously p.3-8
■ "Single-Task Mode" and "Multi-Task Mode"
You can use the two modes appropriately according to the measurement details; for
standard measurement, you can use "Single-Task mode" that can be set easily, and
when you need detailed settings, for example when you measure and judge multiple
characteristic points simultaneously, you can use "Multi-Task mode". In "Multi-Task
mode", four tasks are provided. You can measure and judge multiple characteristic
points simultaneously because you can measure the desired characteristic point such
as peak, bottom, and average for each task.
[Single-Task]
[Multi-Task]
ZS-HL
5-4
User's Manual
Surface fluctuation (TASK2)
Data flow
Data flow of TASK1
Data flow of TASK4
Height (TASK1)
* Output
• Linear output
Select one TASK that you want to output.
• Judgment output
- Select one TASK that you want to output.
- When ZS-RPD is connected, you can
output a judgment for four TASKs.
• Terminal block output
If you connect ZS-RPD, you can
output data for up to four TASKs.
• Digital output (USB/RS-232C)
Continuously outputs four TASKs.
It is used to display a
graph screen or do
logging with SmartMonitor
ZS or external devices.

Hide quick links: