Error Messages and Countermeasures

■ When [Error] Is Displayed on the Main Display
Display Details
LCD
Overcurrent
screen
(upper
Dark Error
section)
Bright Error
Measure Error
■ When all digits on the main display and sub-display blink
Display Details
LCD screen
SYSTEM ERROR
HEAD COM (EEPROM)
SYSTEM ERROR
BANK DATA
SYSTEM ERROR
MAIN COM
■ Others
Display Details
LCD upper
Disp range Error
section
Main display ––––––

Error Messages and Countermeasures

Cause
Individual or groups of judgment
outputs are short-circuited.
Insufficient received light amount
from workpiece. Distance mea-
surement error.
Saturated received light amount
from the workpiece. Distance
measurement error.
When [NORMAL], [PCB], and
[MIRROR] are set for the mea-
surement object, the number of
surfaces currently being mea-
sured is 2 or more.
Alternatively, when [GLASS] is set
for the measurement object, the
number of surfaces currently
being measured is 4 or more.
Cause
The Sensor Head is not con-
nected.
Bank data in the Sensor Control-
ler in error
Internal error
Cause
The measurement
result exceeds the
number of displayed
digits.
The sensor is standing
by for measurement.
Countermeasure
Cancel the load short-circuit.
For a workpiece with regular reflection
(glass)
• Check the angle at which the Sensor
Head is attached.
For a workpiece with diffuse reflection
• Set to High-Sensitivity mode.
• Set the gain setting to 2 or higher.
• Set to High-Speed mode.
• Set the gain setting to 1.
For a workpiece with regular reflection
(glass)
• Check the angle at which the Sensor
Head is attached.
For a workpiece with diffuse reflection
• Set to GLASS mode.
• Using SmartMonitor ZS, set the
measurement area to the surface
you want to measure.
Countermeasure
Connect the Sensor Head.
Hold the UP key down for 3 sec-
onds, and then hold the DOWN
key down for 3 seconds.
The sensor is turned ON again
and restored after the device is
initialized.
Turn the Controller ON again.
Countermeasure
Change the decimal point digit setting.
p.5-25
When hold is set, start sampling and apply the
hold value.
Section9
ZS-HL
9-3
User's Manual