Section 3
Settings during application extended connection

Specifying the Amplifier Unit to input the trigger

Set whether or not to input the TRIG signal to an Amplifier Unit.
MENU Mode-[SYS2]-[LINKSET]-[TRIG]
Setting
I/O (default value)
LINK

Setting the presence of Sensor Head

Set whether or not a Sensor Head is connected.
MENU Mode-[SYS2]-[LINKSET]-[HEAD]
Setting
USE (default value)
NOT USE

Setting output content

Set the output content of the measurement result.
This item is displayed only the Amplifier Unit whose [TRIG/TRIG] setting is set to [I/O].
MENU Mode-[SYS2]-[LINKSET]-[OUTPUT]
Setting
ALL
EACH (defalut value)
ZFV
64
User's Manual
Set to only the Amplifier Unit to which the TRIG signal is to be input.
Synchronizes to the TRIG signal from the Amplifier Unit gang-mounted on the right
side.
Select this for Amplifier Unit to which a Sensor Head is currently connected.
Measurement is performed using the input image from the currently connected
Sensor Head.
Select this for Amplifier Unit to which a Sensor Head is currently not connected.
Measurement is performed from the image transferred from the Sensor Head
gang-mounted on the right side.
The measurement results of all gang-mounted Amplifier Units are integrated, and
output as an overall judgment result.
The measurement result of each Amplifier Unit is output from the respective Ampli-
fier Unit.
Description
Description
Description