Debugging Using the CX-Programmer

4-1 Debugging Using the CX-Programmer

Operation of the CX-Programmer
Transfer/compare a program.
Monitoring
Force Set/Reset and Set/Reset Bits Force Set/Reset and Set/Reset Bits are possible even
Change the present value of a
word.
Change the set value of the
Timer/Counter.
Detect a rising/falling edge (differ-
ential monitor)
Online Editing
Data Trace/Time Chart Monitoring
Cycle Time Display
Occurring Error and Error History
Display
Register/Set a Password
Read/Set Clock
Release an access right
102
Debugging using the CX-Programmer can be performed in the same operation
as the CS/CJ/CP-series PLC because the CX-Simulator implements equiva-
lent functions as the CS/CJ/CP-series PLC.
Note For details of program debugging with CX-Programmer, refer to the
CX-Programmer Operation Manual (W446).
This section shows the differences with the actual CS/CJ/CP-series PLC and
notices when operating the CX-Simulator from the CX-Programmer.
Note When operating the Ladder Engine only from the CX-Programmer and not
from the CX-Simulator Debug Console (in the Monitor mode and in Continuous
Run), the same operation as when the CS/CJ-series CPU Unit is connected to
the CX-Programmer can be performed.
Differences/Notices
Same
Monitoring is possible even during a scan when in Step
Run.
during a scan when in Step Run.
Changing the present value of a word is possible even
during a scan when in Step Run.
Changing the set value of the Timer/Counter is possible
even during a scan when in Step Run.
Differential monitor is possible even during a scan when in
Step Run.
Online Editing is possible even during Step Run and scan.
Online Editing during Step Run (including Continuous Step
Run) will return the program control to the head (when
Online Editing enabled for Scan Replay/ Step Run).
The time axis (the horizontal axis) of the time chart moni-
toring shows the different time with that of the
CX-Simulator operation when in the virtual cycle time mode
or pausing.
Setting from the CX-Simulator allows to display the cycle
time in the virtual cycle time or computer cycle time.
Same
Same
Same (The day of the week is automatically corrected
following the calendar in the CX-Simulator.)
Same
Section 4-1