I/O Memory Allocation
Address
Words
Bits
A295
A29511 No END
Error Flag
A29512 Task Error
Flag
A29513 Differentia-
tion Over-
flow Error
Flag
A29514 Illegal In-
struction
Error Flag
A29515 UM Over-
flow Error
Flag
A298
All
Program
Address
Where
Program
Stopped
(Rightmost
4 digits)
212
Name
ON when there isn't an END(001)
instruction in each program within
a task.
CPU Unit operation will stop and
the ERR/ALM indicator will light
when this flag goes ON.
(The task number where the error
occurred will be stored in A294
and the program address will be
stored in A298 and A299.)
ON when a task error has oc-
curred. The following conditions
generate a task error.
There isn't even one regular task
that is executable (started).
There isn't a program allocated
to the task.
(The task number where the
error occurred will be stored in
A294 and the program address
will be stored in A298 and A299.)
The allowed value for Differentia-
tion Flags which correspond to
differentiation instructions has
been exceeded. CPU Unit opera-
tion will stop and the ERR/ALM
indicator will light when this flag
goes ON.
(The task number where the error
occurred will be stored in A294
and the program address will be
stored in A298 and A299.)
ON when a program that cannot
be executed has been stored.
CPU Unit operation will stop and
the ERR/ALM indicator will light
when this flag goes ON.
(The task number where the error
occurred will be stored in A294
and the program address will be
stored in A298 and A299.)
ON when the last address in UM
(User Memory) has been ex-
ceeded. CPU Unit operation will
stop and the ERR/ALM indicator
will light when this flag goes ON.
These words contain the 8-digit
binary program address of the
instruction where program exe-
cution was stopped due to a
program error.
CS/CJ-series PLC
Function
CX-Simulator
Settings
Function
1: No END
Same as
0: Normal
CS/CJ-series
condition
PLC.
1: Error
Same as
CS/CJ-series
0: Normal
PLC.
1: Error
Same as
CS/CJ-series
0: Normal
PLC.
1: Error
Same as
CS/CJ-series
0: Normal
PLC.
1: Error
Same as
CS/CJ-series
0: Normal
PLC.
Right 4
Same as
digits of the
CS/CJ-series
program
PLC.
address
Section 9-3
Settings