How to Use Data Trace Recording Tool
Operation of Data Trace Recording Tool
256
Input format
Area string = Area symbol + Word range + Bit range
Area symbol
Word range
Bit range
Input example: CIO000101 (CIO 1word, 1 bit)
Note How to specify for an EM bank
Specify with "-"(hyphen) × Number of banks (Decimal) after the EM address.
(Example: E32767-12 for address 32767 and bank 12)
Note Before using the Data Trace Recording Tool, make sure that the FinsGateway
Service Manager is started and the communications unit of the network where
CPU_UNIT and the target PLC are connected is servicing.
Staring Procedure
1,2,3...
1. Select the Data Trace Recording Tool from [Start] | [Program] | [Omron] |
[CX-Simulator] to display the execution window of the Data Trace Re-
cording Tool.
Area symbols in the above table (Uppercase charac-
ters)
Specify "word." (Decimal)
Specify for the number in the table.
(Example: 000016 for address 16 and number of digit 6)
Specify "bit." (Decimal)
Specify for the number in the table.
(Example: 08 for address 8 and number of digit 2)