Example 4
The value of the parameter P_GAIN two times the value in example 1. The
Following Error is half, but there is vibration due to the excessive gains.
The parameter values for the example are:
/i
Motion Parameter values
P_Gain=262144
VFF_GAIN=0
Fn001=6
Section 5-1