Omron SYSMAC CJ Operation Manual page 19

Sysmac cj-series programmable controller motion control unit
Hide thumbs Also See for SYSMAC CJ:
Table of Contents

Advertisement

Motion control concepts
1-3-1-2 Continuous moves
1-3-2
CP control
1-3-2-1 Linear interpolation
Deceleration distance
Constant speed distance
Total time
The FORWARD and REVERSE commands can be used to start a continuous
movement with constant speed on a certain axis. The FORWARD command
moves the axis in positive direction and the REVERSE command in negative
direction. For these commands also the axis parameters ACCEL and SPEED
apply to specify the acceleration rate and demand speed.
Both movements can be cancelled by using either the CANCEL or
RAPIDSTOP command. The CANCEL command cancels the move for one
axis and RAPIDSTOP cancels moves on all axes. The deceleration rate is set
by DECEL.
Continuous Path control enables to control a specified path between the start
and end position of a movement for one or multiple axes. The CJ1W-MCH72
supports the following operations:
Linear interpolation
Circular interpolation
CAM control.
B
=
=
=
2
3
Section 1-3
1
A
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysmac cj1w-mch72

Table of Contents