Change Exception Reporting Thresholds Input Form, Page 1 - Paradyne COMSPHERE 6800 Series Command Reference Manual

Network management system, communications products support
Table of Contents

Advertisement

Figure 2-13. Change Exception Reporting Thresholds Input Form, Page 1
This input form contains the following fields:
Request Terminal Power: list if (Required field)
Digital: list if > nnnn errors (Required field)
End to End: list if > nnnn inbound errors (Required field)
End to End: list if > nnnn outbound errors (Required field)
Circuit Loss Inbound: list if > nn dB (Required field)
6800-A2-GB31-20
Specify whether the exception report for the Report Terminal Power (rtp) command will
indicate an on or off (default) power state of the terminal connected to a device's data
channel. A pop-up menu is available listing valid selections.
Enter the exception reporting threshold for the number of bits in error (determined when a
Digital Test (dt) command is run). Valid entries are from 0 (default) through 1000.
Enter the exception reporting threshold for the number of inbound bits in error
(determined when an End-to-End Test (eet) command is run). Valid entries are from
0 (default) through 1000.
Enter the exception reporting threshold for the number of outbound bits in error
(determined when an End-to-End Test (eet) command is run). Valid entries are from
0 (default) through 1000.
Enter the exception reporting threshold for inbound circuit loss in decibels (determined
when the Circuit Loss Inbound (cli) command is run). Valid entries are from 0 through 30.
The default is 16.
A pop-up menu is available listing valid selections.
January 1997
2Modem/DSU Commands
2-49