Parameters
5-12 Terminal 27 Digital Input
Parameter for configuring the input function on input terminal
27.
Option:
[0]
3
3
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[14]
[16]
[17]
[18]
[19]
[20]
[21]
[22]
[23]
[34]
[37]
[52]
[53]
[54]
[60]
[61]
[62]
[63]
[64]
[65]
5-13 Terminal 29 Digital Input
Parameter for configuring the input function on input terminal
29.
Option:
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[14]
*
42
No operation
Reset
Coast inverse
Coast and reset inverse
Quick stop inverse
DC-brake inverse
Stop inverse
External Interlock
Start
Latched start
Reversing
Start reversing
Jog
Preset ref bit 0
Preset ref bit 1
Preset ref bit 2
Freeze reference
Freeze output
Speed up
Speed down
Set-up select bit 0
Ramp bit 0
Fire Mode
Run permissive
Hand start
Auto start
Counter A (up)
Counter A (down)
Reset Counter A
Counter B (up)
Counter B (down)
Reset Counter B
No operation
Reset
Coast inverse
Coast and reset inverse
Quick stop inverse
DC-brake inverse
Stop inverse
External Interlock
Start
Latched start
Reversing
Start reversing
Jog
TR150 Programming Guide
5-13 Terminal 29 Digital Input
Parameter for configuring the input function on input terminal
29.
Function:
Option:
[16]
[17]
[18]
[19]
[20]
[21]
[22]
[23]
[32]
[34]
[37]
[52]
[53]
[54]
[60]
[61]
[62]
[63]
[64]
[65]
5-34 On delay, Terminal 42 Digital Output
Range:
0.01 s
*
5-35 Off delay, Terminal 42 Digital Output
Range:
0.01 s
*
3.6.3 5-4* Relays
Parameters for configuring the timing and the output
functions for the relays.
5-40 Function Relay
Array (Relay 1 [0], Relay 2 [1])
Function:
Select options to define the function of the relays.
The selection of each mechanical relay is realised in an array
parameter.
Option:
[0]
No operation
[1]
Control Ready
[2]
Drive ready
[3]
Drive ready/
remote control
BAS-SVP16A-EN - Rev. 2013-09-05
Preset ref bit 0
Preset ref bit 1
Preset ref bit 2
Freeze reference
Freeze output
Speed up
Speed down
Set-up select bit 0
Pulse input
Ramp bit 0
Fire Mode
Run permissive
Hand start
Auto start
Counter A (up)
Counter A (down)
Reset Counter A
Counter B (up)
Counter B (down)
Reset Counter B
Function:
[0.00-600.00 s]
Function:
[0.00-600.00 s]
Function:
Default for both relays
Control board receives supply voltage.
Frequency converter is ready for
operation and applies supply signal on
control board.
Frequency converter is ready for
operation in Auto mode.
Function:

Advertisement