5-14 Replacing modules in a copper-distribution shelf
Procedure 5-4 (continued)
Replacing the NT4K73AA or NT4K73CA metallic test access card
Step
9
10
11
Figure 5-7
Withdrawing an MTAC
Metallic test access card
AccessNode P0904244 Issue 1.0
Action
Change the state of the MTAC to in-service (IS):
chgstate is↵
The state changes to IS.
Note: If the automatic-in-service feature is set to on, the state changes to IS
automatically.
Gently push in the CDS line drawer until the handle comes in contact with the
shelf. Then push the line drawer in to engage the handle with the shelf.
Lock the CDS line drawer ejector latch by turning the locking screw 90
degrees clockwise so that the alignment indicators are aligned.
—end—