Lenovo ThinkSystem ST650 V2 Setup Manual page 15

Hide thumbs Also See for ThinkSystem ST650 V2:
Table of Contents

Advertisement

Table 1. Specifications (continued)
Specification
Environment
Acoustical noise
emissions
Description
The ThinkSystem ST650 V2 server complies with ASHRAE Class A2 specifications.
Depending on the hardware configuration, some models comply with ASHRAE Class A3
and Class A4 specifications. System performance may be impacted when operating
temperature is outside ASHRAE A2 specification.
• Air temperature:
– Operating
– ASHRAE Class A2: 10°C to 35°C (50°F to 95°F); the maximum ambient
temperature decreases by 1°C for every 300 m (984 ft) increase in altitude
above 900 m (2,953 ft).
– ASHRAE Class A3: 5°C to 40°C (41°F to 104°F); the maximum ambient
temperature decreases by 1°C for every 175 m (574 ft) increase in altitude
above 900 m (2,953 ft).
– ASHRAE Class A4: 5°C to 45°C (41°F to 113°F); the maximum ambient
temperature decreases by 1°C for every 125 m (410 ft) increase in altitude
above 900 m (2,953 ft).
– Server off: -10°C to 60°C (14°F to 140°F)
– Shipment/storage: -40°C to 60°C (-40°F to 140°F)
• Maximum altitude: 3,050 m (10,000 ft)
• Relative Humidity (non-condensing):
– Operating
– ASHRAE Class A2: 8% to 80%; maximum dew point: 21°C (70°F)
– ASHRAE Class A3: 8% to 85%; maximum dew point: 24°C (75°F)
– ASHRAE Class A4: 8% to 90%; maximum dew point: 24°C (75°F)
– Shipment/storage: 8% to 90%
• Particulate contamination
Attention: Airborne particulates and reactive gases acting alone or in combination
with other environmental factors such as humidity or temperature might pose a risk to
the server. For information about the limits for particulates and gases, see
"Particulate contamination" in ThinkSystem ST650 V2 Maintenance Manual.
The server has the following acoustic noise emissions declaration:
• Sound power level (L
WAd
– Idling:
– Min: 5.0 Bel
– Typical: 5.6 Bel
– GPU: 6.4 Bel
– Operating:
– Min: 5.6 Bel
– Typical: 5.6 Bel
– GPU: 8.2 Bel
• Sound pressure level (L
– Idling:
– Min: 37 dBA
– Typical: 41 dBA
– GPU: 48 dBA
– Operating:
– Min: 41 dBA
– Typical: 41 dBA
– GPU: 66 dBA
)
):