Lenovo ThinkSystem ST650 V2 Setup Manual page 13

Hide thumbs Also See for ThinkSystem ST650 V2:
Table of Contents

Advertisement

Table 1. Specifications (continued)
Specification
Onboard NVMe
connectors
Input/Output (I/O)
features
Network
Storage controller
Description
Four onboard NVMe connectors are available:
• PCIe 1: Gen3
• PCIe 2: Gen3
• PCIe 3: Gen4
• PCIe 4: Gen4 when connected to backplane, Gen3 when connected to PCIe slot 8
enable connector.
• Front panel
– One USB 2.0 connector with Lenovo XClarity Controller management
– One USB 3.2 Gen 1 connector
• Rear panel
– One External LCD diagnostics handset connector
– Four USB 3.2 Gen 1 connectors
– Two 10Gb Ethernet connectors
– One VGA connector
– One serial-port-module slot
– One XClarity Controller network connector (RJ-45 Ethernet connector)
• Two 10Gb ethernet connectors
• One XClarity Controller network connector (RJ-45 Ethernet connector)
Note: Use CAT6A UTP cables rated at 625 MHz bandwidth for the 10Gb on-board
LAN.
• Twelve onboard SATA ports (only the first 8 drives can be configured using Intel
VROC SATA RAID)
• Eight onboard NVMe ports (Intel VROC NVMe RAID)
• NVMe Retimer Adapter (Intel VROC NVMe RAID)
• The following SAS/SATA RAID/HBA options are available for this server:
– ThinkSystem 430-8i SAS/SATA 12Gb HBA (No RAID)
– ThinkSystem 430-8e SAS/SATA 12Gb HBA (No RAID)
– ThinkSystem 430-16i SAS/SATA 12Gb HBA (No RAID)
– ThinkSystem 430-16e SAS/SATA 12Gb HBA (No RAID)
– ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb Internal HBA (No RAID)
– ThinkSystem RAID 530-8i PCIe 12Gb Adapter (RAID 0, 1, 10, 5, 50)
– ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter (RAID 0, 1, 10, 5, 50, 6,
60)
– ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter (RAID 0, 1, 10, 5, 50, 6,
60)
– ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter (RAID 0, 1, 10, 5,
50, 6, 60)
– ThinkSystem RAID 940-8i 8GB Flash PCIe Gen4 12Gb Adapter (RAID 0, 1, 10, 5,
50, 6, 60)
– ThinkSystem RAID 530-16i PCIe 12Gb Adapter (RAID 0, 1, 10)
– ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter (RAID 0, 1, 10, 5, 50, 6,
60)
– ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Adapter (RAID 0, 1, 10, 5,
50, 6, 60)
– ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Internal Adapter (RAID 0,
1, 10, 5, 50, 6, 60)
– ThinkSystem RAID 940-32i 8GB Flash PCIe Gen4 12Gb Adapter (RAID 0, 1, 10, 5,
50, 6, 60)
Note: ThinkSystem RAID 940-32i 8GB Flash PCIe Gen4 12Gb Adapter can only be
installed in slot 9 in one CPU configurations, and installed in slot 9, 5, 6, 7, or 8 in two
CPU configurations.
For a list of supported adapters, see:
https://static.lenovo.com/us/en/serverproven/index.shtml
.
Chapter 1
Introduction
5

Advertisement

Table of Contents
loading

Table of Contents