Olivetti d-Copia 3001MF Service Manual page 87

Hide thumbs Also See for d-Copia 3001MF:
Table of Contents

Advertisement

2K5
Maintenance
item No.
Checking/clearing the fuser counts
U167
Description
Displays and clears the fuser counts for checking.
Purpose
To check the fuser count after replacement of the fuser unit. Also to clear the counts after replacing unit.
Method
1. Press the start key. The fuser counts is displayed.
Clearing
1. Select [CLEAR].
2. Press the start key. The count is cleared.
Setting
1. Change the count using the +/- or numeric keys.
2. Press the start key. The count is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Setting the fuser drive control
U193
Description
Specifies ON/OFF the fuser drive control.
Purpose
Countermeasure against black dots which is caused by toner adhering to the heat roller separation claws.
Setting
1. Press the start key.
2. Select ON or OFF.
Display
ON
OFF
Initial setting: ON
3. Press the start key. The setting is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
1-3-52
Description
Description
Fuser drive control ON
Fuser drive control OFF
Service Manual
Y112040-6

Advertisement

Table of Contents
loading

Table of Contents