Olivetti d-Copia 3001MF Service Manual page 168

Hide thumbs Also See for d-Copia 3001MF:
Table of Contents

Advertisement

Code
C3100
Scanner carriage problem
The home position is not correct when
the power is turned on or at the start of
copying using the table.
C3200
Exposure lamp problem
When input value at the time of exposure
lamp illumination does not exceed the
threshold value between 5 s.
C3300
Optical system (AGC) problem
After AGC, correct input is not obtained
at CCD.
C3500
Communication error between scan-
ner and SHD
An error code is detected.
Y112040-6
Contents
Causes
Check procedures/corrective measures
Poor contact in the
Check the connection of connector YC6 on
connector termi-
the scanner PWB and the connector of the
nals.
home position switch, and the connection of
connector YC3 on the scanner PWB and the
connector on the scanner motor and the
continuity across the connector terminals.
Repair or replace if necessary.
Defective home
Replace the scanner home position switch.
position switch.
Defective scanner
Replace the scanner motor.
motor.
The mirror frame,
Check if the mirror flames and exposure
exposure lamp, or
lamp are on the rail. And check the scanner
scanner wire is
wire winds correctly.
defective.
Defective PWB.
Replace the scanner PWB or main PWB
and check for correct operation.
Poor contact in the
Check the connection of connector YC5 on
connector termi-
the scanner PWB and the connector on the
nals.
inverter PWB, and the continuity across the
connector terminals. Repair or replace if
necessary.
Defective exposure
Replace the exposure lamp.
lamp.
Incorrect shading
Adjust the position of the contact glass
position.
(shading plate). If the problem still occurs,
replace the home position switch.
Defective PWB.
Replace the scanner PWB or inverter PWB
and check for correct operation.
Poor contact in the
Check the connection of connector YC26 on
connector termi-
the main PWB and the connector on the
nals.
CCD PWB, and the continuity across the
connector terminals. Repair or replace if
necessary.
Defective exposure
Replace the exposure lamp.
lamp.
Defective PWB.
Replace the main PWB or CCD PWB and
check for correct operation.
Poor contact in the
Check the connection of connector YC26 on
connector termi-
the main PWB and the connector on the
nals.
CCD PWB, and the continuity across the
connector terminals. Repair or replace if
necessary.
Defective PWB.
Replace the main PWB or CCD PWB and
check for correct operation.
Service Manual