Olivetti d-Copia 3001MF Service Manual page 109

Hide thumbs Also See for d-Copia 3001MF:
Table of Contents

Advertisement

2K5
Maintenance
item No.
Adjusting the leading edge registration for memory image printing
U407
Description
Adjusts the leading edge registration during memory copying.
Purpose
Make the following adjustment if there is a regular error between the leading edge of the copy image on the
front face and that on the reverse face during duplex switchback copying.
Caution
Before making this adjustment, ensure that the following adjustments have been made in maintenance mode.
U034
(P.1-3-22)
U404
(P.1-3-73)
Adjustment
1. Press the start key.
Display
ADJUST DATA Leading edge registration for memory
2. Press the system menu key.
3. Place an original and press the start key to make a test copy.
4. Press the system menu key.
5. Change the setting value using the +/- or numeric keys.
For copy example 1, decrease the value.
For copy example 2, increase the value.
6. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
1-3-74
U402
U066
(P.1-3-71)
(P.1-3-30)
U407
Description
image printing
Original
Service Manual
Description
U403
(P.1-3-72)
Setting
range
-47 to 47
Copy
Copy
example 2
example 1
Figure 1-3-20
U071
(P.1-3-34)
Initial
Change in
setting
value per step
47
0.1 mm
Y112040-6

Advertisement

Table of Contents
loading

Table of Contents