Advertisement

2K5
Maintenance
item No.
Checking/clearing counts by optional devices
U905
Description
Displays the counts of DP or finisher.
Purpose
To check the use of DP and finisher.
Method
1. Press the start key.
2. Select the device, the count of which is to be checked.
3. Press the start key. The count of the selected device is displayed.
Display
DP
FINISHER
DP
Display
ADP
RADP
Document finisher/Built-in finisher
Display
CP CNT
STAPLE
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Resetting partial operation control
U906
Description
Resets the service call code for partial operation control.
Purpose
To be reset after partial operation is performed due to problems in the cassettes or other sections, and the
related parts are serviced.
Method
1. Press the start key.
2. Press [Execute].
3. Press the start key to reset partial operation control.
4. Turn the main power switch off and on.
1-3-86
Description
Description
Counts of optional DP
Counts of optional document finisher or built-in finisher
Description
No. of single-sided originals that has passed through the DP
No. of double-sided originals that has passed through the DP
Description
No. of copies that has passed
Frequency the stapler has been activated