Troubleshooting
Fault
Symptom
A "Disk
Fault"
alarm is
reported
to iBMC.
Issue 12 (2022-08-30)
Handling Procedure
1. If the drive is in a RAID array
and the RAID array is not
functioning correctly,
troubleshoot the RAID array.
2. If the server has stopped, use
Smart Provisioning
the server hardware. If the
server is operating, replace the
drive.
3. If the server has stopped,
check whether the cables are
properly connected. For
example, replace the cables to
check whether the cables are
faulty.
4. If the fault persists, insert the
new drive into the slot that
you suspect to be faulty to
check whether that slot is
faulty.
NOTE
For RAID controller cards that
support out-of-band
management, if a drive is in the
Unconfigured Good (Foreign)
state, an iBMC alarm will be
generated but the fault indicator
will not light up.
Copyright © Huawei Technologies Co., Ltd.
5 Diagnosing and Rectifying Faults
Quick Recovery Method
1. If the faulty drive is not in a
RAID array (except drives in
passthrough mode), the
drive cannot be used and
needs to be replaced. It is
recommended that you
to inspect
configure RAID for all drives
and then deploy the
redundant services.
2. Back up the data of
redundant RAID arrays to
avoid data loss.
3. Follow the handling
procedure to replace any
faulty modules.
56