TaiShan Servers
Troubleshooting
Indicator
100GE optical
port
transmission
rate indicator
Issue 12 (2022-08-30)
Applicable
Product
TaiShan 200
server
(models
XA320 and
XA320C)
Copyright © Huawei Technologies Co., Ltd.
5 Diagnosing and Rectifying Faults
Status
Description
Steady
The current
yellow
data
transmission
rate is 40 Gbit/s.
Steady
The current
green
data
transmission
rate is 100
Gbit/s.
Diagnosis
1. Connect the
port to
another
switch,
optical fiber,
and optical
module to
check
whether the
original
switch and
optical fiber
are normal
and whether
the type and
speed of the
original
optical
module are
correct.
2. Check
whether the
ports on the
switch and
NIC are up.
3. Check
whether the
NIC is
operating
properly.
N/A