Memory Faults - Huawei TaiShan Troubleshooting Manual

Table of Contents

Advertisement

TaiShan Servers
Troubleshooting
Fault
Symptom
RAID self-
check is
suspende
d.
NIC
Preboot
Execution
Environm
ent (PXE)
has failed.

5.6.4 Memory Faults

Diagnose and rectify memory faults depending on the symptoms.
Issue 12 (2022-08-30)
Handling Procedure
1. Capture the current iBMC KVM
or local KVM screen.
2. Collect iBMC logs.
1. Check whether the NIC
supports PXE.
2. Check the BIOS PXE
configuration. Ensure that the
NIC PXE function is enabled.
3. Check the NIC.
4. Check the PXE network
environment on the service
side.
Copyright © Huawei Technologies Co., Ltd.
5 Diagnosing and Rectifying Faults
Quick Recovery Method
1. If a RAID controller card
firmware error exists,
replace the RAID controller
card or supercapacitor. Then
check whether the fault is
rectified.
● If yes, no further action is
required.
● If no, go to 2.
2. Check whether the drives,
drive backplane, and SAS
cables are faulty.
● If yes, replace faulty
components.
● If no, go to 3.
3. If the RAID array is offline,
import it again. Then check
whether the fault is
rectified.
● If yes, no further action is
required.
● If no, go to 4.
4. If the supercapacitor runs
out of power, follow the
instructions shown in the
displayed messages to keep
the server running. After the
server runs for 30 minutes,
check the supercapacitor
status. If the supercapacitor
is abnormal, replace it.
Follow the handling procedure.
53