FrameMaker Ver.6E (PC) magicolor 7300 TROUBLESHOOTING
02.08.08
(2)
white lines in CD, white bands in CD, colored lines in CD, and colored bands in
CD
White lines in
4011T016AA
<Troubleshooting Procedure>
Section
Step
PU
1
The surface of the PC
Drum is scratched.
2
Dirty on the outside.
3
Connectors and contact
terminals make good
connection between each
PU and PH Unit.
4
Developing bias contact
terminal makes good
connection.
Transfer
5
Image Transfer Belt is dirty
Belt Unit
or scratched.
6
2nd Image Transfer Roller
is dirty or scratched.
Paper path
7
There is foreign matter on
paper path.
Fuser Unit
8
Fusing Entrance Guide
Plate is dirty or damaged.
9
Fusing Paper Separator
Fingers are dirty.
10 The problem has been
eliminated by checking up
to Step 9.
<Typical Faulty Images>
White bands
Colored lines
4011T021AA
4011T018AA
Check Item
Result
YES Change PU.
YES Clean.
NO
NO
YES Clean dirty belt with a soft cloth.
YES Replacing the Transfer Belt Unit.
YES Remove foreign matter.
YES Clean.
YES Replacing the Fuser Unit.
NO
T-44
Colored
4011T022AA
Action
Clean contact terminals.
Reconnect.
Clean contact terminal and check
terminal position.
Change Transfer Belt Unit if belt
is damaged.
D-31DISASSEMBLY/REAS-
SEMBLY
Replacing the Fuser Unit.
Change the PU.
Replacing the Transfer Belt Unit.
Replacing the Fuser Unit.